No.
|
Item
|
General Parameter
|
Remark
|
|
|
1 |
Combination method
|
13S25P
|
Single cell 18650 2200mah 3.7v |
|
|
2 |
Combination standard for single cell |
Capacity difference≤2% |
Combination after 0.15C discharge to 2.5V
|
|
|
Resistance difference ≤10mΩ |
||||
|
Voltage difference≤8mV |
||||
|
3 |
Rated Capacity
|
Typical
|
50Ah |
Standard discharge after Standard charge(package)
|
|
Minimum
|
50Ah |
|||
|
4 |
Nominal Voltage
|
48V |
Mean Operation Voltage
|
|
|
5 |
Voltage at end of Discharge
|
42V |
Discharge Cut-off Voltage
|
|
|
6 |
Charging Voltage
|
54.6V |
|
|
|
7 |
Internal Impedance
|
≤100mΩ |
Internal resistance measured at AC 1KHZ after 50% charge
The measure must uses the new batteries that within one week after shipment and cycles less than 5 times
|
|
|
8 |
Standard charge
|
Constant Current 10A Constant Voltage54.6V 0.01CA cut-off
|
Charge time : Approx 6 h
|
|
|
9 |
Standard discharge
|
Constant current:10A end voltage 42V
|
|
|
|
10 |
Maximum Continuous Charge Current
|
50A |
|
|
|
No.
|
Item
|
General Parameter
|
Remark
|
|
11 |
Maximum Continuous Discharge Current
|
50A |
|
|
12 |
Operation Temperature Range
|
Charge: 0~45℃ |
60±25%R.H. Bare Cell
|
|
Discharge: -20~60℃ |
|||
|
13 |
Storage Temperature Range
|
Less than 12 months : -20~25℃
|
60±25%R.H. at the shipment state
|
|
less than 3 months: -20~40℃
|
|||
|
Less than 7 day : -20~65℃
|
|||
|
14 |
Dimensions
|
L440*W440*T88(mm) |
including the outer shell |
|
15 |
Weight
|
18kg |
ncluding the outer shell |


1) The BMS is designed for 13 series lithium battery.
2) The BMS have all functions which are :
Overcharge detection function
Over discharge detection function
Over current detection function
Short detection function
Balance function
Temperature detection
If you are designing new residencial back up power with energy of bigger capacity , you can parelle two or more standard module, we can provide all equipment including of the battery storage charger bms inverter or other compenents such us display unit , romote motering and etc with your require.

The Energy storage system protected by thicken spongebox
1 set / 1 box , 1 box for 1 thicken standard export carton